general.endergenic.endergenicSendPerTick changed by FTB StoneBlock 4The amount of RF per tick that this generator can give from its internal buffer to adjacent blocks config/rftoolspower-server.toml | 50000 | 20000 |
general.endergenic.powergenFactor changed by FTB StoneBlock 4Multiplier for power generation config/rftoolspower-server.toml | 2.2 | 2 |
general.blazing.blazingAgitatorMaxPower Maximum amount of power the blazing agitator can store config/rftoolspower-server.toml | 50000 | 50000 |
general.blazing.blazingAgitatorRFPerTick Amount of RF per tick input (per side) for the agitator config/rftoolspower-server.toml | 100 | 100 |
general.blazing.blazingAgitatorUsePerTick Amount of RF per tick the agitator uses while operating config/rftoolspower-server.toml | 10 | 10 |
general.blazing.blazingGeneratorMaxPower Maximum amount of power the blazing generator can store config/rftoolspower-server.toml | 1000000 | 1000000 |
general.blazing.blazingGeneratorSendPerTick Maximum amount of power the blazing generator give to adjacent machines per side and per tick config/rftoolspower-server.toml | 20000 | 20000 |
general.blazing.blazingInfuserMaxPower Maximum amount of power the blazing infuser can store config/rftoolspower-server.toml | 50000 | 50000 |
general.blazing.blazingInfuserRFPerTick Amount of RF per tick input (per side) for the infuser config/rftoolspower-server.toml | 100 | 100 |
general.blazing.blazingInfuserUsePerTick Amount of RF per tick the infuser uses while operating config/rftoolspower-server.toml | 10 | 10 |
general.coalgenerator.generatePerTick Amount of RF generated per tick config/rftoolspower-server.toml | 60 | 60 |
general.coalgenerator.generatorChargePerTick RF per tick that the generator can charge items with config/rftoolspower-server.toml | 1000 | 1000 |
general.coalgenerator.generatorMaxRF Maximum RF storage that the generator can hold config/rftoolspower-server.toml | 500000 | 500000 |
general.coalgenerator.generatorRFPerTick RF per tick that the generator can send config/rftoolspower-server.toml | 2000 | 2000 |
general.coalgenerator.ticksPerCoal Amount of ticks generated per coal config/rftoolspower-server.toml | 600 | 600 |
general.dimensionalcell.advancedFactor How much better is the advanced cell with RF and RF/t config/rftoolspower-server.toml | 4 | 4 |
general.dimensionalcell.powercellChargePerTick RF per tick that the powrcell can charge items with config/rftoolspower-server.toml | 30000 | 30000 |
general.dimensionalcell.powerCellCostFactor The maximum cost factor for extracting energy out of a powercell for blocks in other dimensions or farther away then 10000 blocks config/rftoolspower-server.toml | 1.1 | 1.1 |
general.dimensionalcell.powerCellDistanceCap At this distance the cost factor will be maximum. This value is also used when power is extracted from cells in different dimensions config/rftoolspower-server.toml | 10000 | 10000 |
general.dimensionalcell.powerCellMinDistance As soon as powercells are not connected this value will be taken as the minimum distance to base the cost factor from config/rftoolspower-server.toml | 100 | 100 |
general.dimensionalcell.powerCellRFToolsDimensionAdvantage A multiplier for the distance if RFTools dimensions are involved. If both sides are RFTools dimensions then this multiplier is done twice config/rftoolspower-server.toml | 0.5 | 0.5 |
general.dimensionalcell.rfPerNormalCell Maximum RF storage that a single cell can hold config/rftoolspower-server.toml | 1000000 | 1000000 |
general.dimensionalcell.rfPerTick Base amount of RF/tick that can be extracted/inserted in this block config/rftoolspower-server.toml | 5000 | 5000 |
general.dimensionalcell.simpleFactor How much worse is the simple cell with RF and RF/t config/rftoolspower-server.toml | 4 | 4 |
general.endergenic.endergenicBadParticles The amount of particles to spawn whenever a pearl is lost (use 0 to disable) config/rftoolspower-server.toml | 10 | 10 |
general.endergenic.endergenicChanceLost The chance (in 1/10 percent, so 1000 = 100%) that an endergenic pearl is lost while trying to hold it config/rftoolspower-server.toml | 5 | 5 |
general.endergenic.endergenicGoodParticles The amount of particles to spawn whenever energy is generated (use 0 to disable) config/rftoolspower-server.toml | 10 | 10 |
general.endergenic.endergenicKeepRf The amount of RF that every endergenic will keep itself (so that it can hold pearls) config/rftoolspower-server.toml | 2000 | 2000 |
general.endergenic.endergenicMaxPower Maximum amount of power the endergenic can store config/rftoolspower-server.toml | 5000000 | 5000000 |
general.endergenic.endergenicRfHolding The amount of RF that is consumed every tick to hold the endergenic pearl config/rftoolspower-server.toml | 500 | 500 |
general.powercell.networkMax Maximum number of blocks in a single multiblock network config/rftoolspower-server.toml | 729 | 729 |
general.powercell.rfPerTickScale How much extra RF/tick every cell gets per cell in the network. 0 means constant RF/t. 1 means linear with amount of cells config/rftoolspower-server.toml | 0.25 | 0.25 |
general.powercell.tier1MaxRF Maximum RF a single tier1 cell can hold config/rftoolspower-server.toml | 500000 | 500000 |
general.powercell.tier1MaxRFPerTick Maximum RF/tick per side for a tier1 cell config/rftoolspower-server.toml | 250 | 250 |
general.powercell.tier2MaxRF Maximum RF a single tier2 cell can hold config/rftoolspower-server.toml | 4000000 | 4000000 |
general.powercell.tier2MaxRFPerTick Maximum RF/tick per side for a tier2 cell config/rftoolspower-server.toml | 1000 | 1000 |
general.powercell.tier3MaxRF Maximum RF a single tier3 cell can hold config/rftoolspower-server.toml | 20000000 | 20000000 |
general.powercell.tier3MaxRFPerTick Maximum RF/tick per side for a tier3 cell config/rftoolspower-server.toml | 4000 | 4000 |